Installation and Operation Manual Gas Cooktops Series RN8200G RN8400G RN8600G RN8800G Date Purchased Serial Number Dealer Service Provider 228605
8 Dimensions Dimensions for Refrigerated Base Models RN8200G and RN8400G models - not available in Refrigerated Base option. RN8600G-RB RN8800G-RB Ref
9 Dimensions Cooktop Options RN8200G RN8400G RN8800G RN8803G RN8806G RN8809G RN8600G RN8603G RN8606G RN8609G RN8203G RN8403G RN8406G NOTE: • RN8200G
10 Installation Requirements NOTE: • It is most important that this Cooktop is installed correctly and that operation is correct before use. Instal
11 Clearances NOTE: Only non-combustible materials can be used in close proximity to this appliance. * Side clearances can be 50mm when the adja
12 Rear Adjustable Feet, fitting:- a. Secure the rear of the base tray to the rear cooktop legs by screwing the two adjustable feet supplied, into t
13 Fitting Adjustable Feet / Rear Rollers to Cabinet and Refrigeration Bases. Rear Adjustable Feet, fitting:- 1. Raise the appliance from the floor b
14 Gas Connection NOTE: ALL GAS FITTING MUST ONLY BE CARRIED OUT BY A QUALIFIED PERSON. 1. Waldorf Cooktops do not require electrical connection, a
15 Commissioning 1. Before leaving the new installation; a. Check the following functions in accordance with the operating instructions specified in
16 Operation Operation Guide 1. Waldorf appliances have been designed to provide simplicity of operation and 100% safety protection. 2. Improper ope
17 Open Burners NOTE: Only cooking pans from size Ø 150mm to Ø 420mm are suitable fo use on these open burners. Flame Failure Option (F-Models) Ligh
The reproduction or copying of any part of this manual by any means whatsoever is strictly forbidden unless authorized previously in writing by the ma
18 Griddle These griddles are fitted with a pilot as a standard option and Flame Failure Protection, which is incorporated by way of a thermo-electric
19 General Clean the Cooktop regularly. A clean Cooktop looks better, will last longer and will perform better. Carbonised grease on the surface or
20 Daily Cleaning 1. The grease / spill tray(s) should be checked and emptied frequently to prevent overflow and spillage. Remove the spill tray(s)
21 Trivets and Burners a. Remove the trivets from the top of the appliance, taking note that the trivets are manufactured with a lip on one edge, the
22 NOTE: It is imperative that the trivet supports are correctly re-fitted to the appliance to ensure that the trivets locate correctly and sit flush
23 Fault Finding This section provides an easy reference guide to the more common problems that may occur during the operation of your equipment. The
24 Conversion Procedure NOTE: • These conversions should only be carried out by qualified persons. All connections must be checked for leaks before
25 11. Turn on the gas supply at the mains, re-light the burners and check the flame size on the simmer (LOW) position. NOTE: The right hand gas co
26 • For the Refrigerated Base Model, the Rating Plate is located inside the right hand front panel and can be viewed through the upper grille. Refe
27 Griddle Pilot Burner a. With the gas supply turned off at the main supply, remove the griddle plate section by lifting it straight off the Cooktop
1 Waldorf Gas Cooktops RN8200G Gas Cooktop 300mm wide. RN8400G Gas Cooktop 600mm wide. RN8600G Gas Cooktop 900mm wide. RN8800G Gas Cookt
28 Gas Regulator NOTE: The regulator supplied is convertible between Natural Gas and LP Gas, but it’s outlet pressure is fixed ex-factory and is NOT
29 Gas Specifications - Australia / New Zealand Only - UK Only Appliance Classification Category: II2H3P. Flue Type: A1. * The burner operat
30 Replacement Parts List When ordering replacement parts, please quote the part number and the description as listed below. If the part required is
31 General 227015 Pot Stand / Trivet. 228881 Spill Tray 300mm (RN8200G Series). 228882 Spill Tray 600mm (RN8400G / RN8800G Series). 228883 Spill
32
33
2 Introduction We are confident that you will be delighted with your WALDORF GAS COOKTOPS, and it will become a most valued appliance in your commerci
3 Specifications Model Numbers Covered in this Specification RN8200G[1]-[2] 2 Open Burners. RN8203G-[2] 300 mm Griddle. RN8400G[1]-[2] 4 Open B
4 Specifications Gas Supply Requirements - Non - UK Only: - UK Only: Appliance Classification Category: II2H3P. Flue Type: A1. * - The burner
5 Dimensions Dimensions for Bench Models RN8200G-B RN8400G-B RN8600G-B RN8800G-B Refer to Page 9 for Cooktop options = Rating Plate Location for this
6 Dimensions Dimensions for Cabinet Base Models RN8200G models - not available in Cabinet Base option. RN8400G-CB RN8600G-CB RN8800G-CB Refer to Page
7 Dimensions Dimensions for Leg Stand Models RN8200G models - not available in Leg Stand Base option. RN8400G-LS RN8600G-LS RN8800G-LS Refer to
Komentáře k této Příručce